• CHECK.....availability of blasting shelter, your blasting equipment, the face, the drill pattern, exposure within and around the blast area, availability of adequate stemming
  • DIAGRAM.....the shot as drilled, delay timings
  • MEASURE.....burden, spacing and depth, noting any deviations
  • CALCULATE.....the powder factor
  • INSURE.....adequate trained personnel on blast crew
  • LOAD.....so shot can be fired prior to completion of loading in case of emergency (weather, equipment breakdown, etc.)
  • CLEAN.....shot area prior to hook-up
  • CLEAR.....blast area after hook-up
  • UTILIZE.....blasting shelter and adequate cover for all in the blast area
  • RECEIVE.....distinct "clear to fire" signal
  • CHECK.....post blast area for safe re-entry
  • GIVE....."clear to re-enter" signal
  • COMPLETE.....shot report with diagram

AND ALWAYS USE COMMON SENSE!

Evacuate blast area when electrical storms threaten.


SAFETY POLICY | CORPORATE GOALS | QUALITY POLICY
LEGAL DISCLAIMER
| REFERENCES